Technical assessment of 18 silos. The reinforced concrete silos are 50m high and located in North Port of Gdansk.

Technical assessment was prepared in 2017.

Technical analysis of the influence of the newly designed building in Gdansk - Wrzeszcz on the neighboring, existing buildings.

Technical assessment was prepared in November 2017.

Technical assessment of reasons of cracks in reinforced - concrete floor in single family house located in Zukowo with recommendation on repair's method.

Technical assessment was prepared in August 2017.

Technical assessment of reasons of cracks in prefabricated container for liquid.

Technical assessment was prepared in 2017.

Technical assessment and reinforcement design of the existing floor in a production - social building at Dr. Oetker factory in Lebcz, Poland.

Description: Technical assessment and vast material tests were performed to enable introduction of additional storey upon an existing ground floor production - warehouse building. The following elements were designed: reinforcement of existing foundations, new columns, reinforcements of structural connections of RC- beams, reinforcement of RC-slab which area excided 1.500m2. Building and detail designs of the steel frame structure of the new storey were prepared. The designs were prepared in the period of 11.2014 - 06.2015.

Technical assessment considering the possibility of supporting of cyclo-filter on an existing RC silo located at STEICO plant in Czarna Woda.

Technical assessment was prepared in September 2015.

Technical assessment of the load capacity and the reinforcement technology of the internal wall at sewage treatment plant in Stegna, wok. pomorskie.

Technical assessment was prepared in October 2015.

Technical assessment considering subsoil settlements impact on the structure of the event and sports hall in woj. pomorskie.

Technical assessment was prepared in March 2015.

FEM calculations of the existing RC dome of the Maritime terminal in Gdynia ( today Muzeum of Emigration).

FEM calculations and study were performed as a part of a technical assessment prior to the reconstruction of the Maritime Terminal in Gdynia at ul. Polska 1. The FEM study considered the safety and durability of the dome. The expertise work was performed in November 2013.

Technical assessment of reasons of cracks and leakiness in two water tanks located in the North Port in Gdansk.

Technical assessment was prepared in 2013.

Technical assessment of cracks in RC columns in a sports and event hall.

Technical assessment was prepared in 2012.

Verification of compliance of reinforcement layout with the detail design of the RC structure in Shakespeare's theater in Gdansk.

lectromagnetic scanning of reinforcement bars and removal of concrete cover to investigate the bars' diameters and their layout. Tests performed to prove the compliance of the work done by former contractor of the structure.

Verification of the detail design of three RC silos for wood chips of 4.700m3 volume located at EC DALKIA plant in Lodz.

Verification of structural and material design and static-strength calculations together with recommendations of alternative solutions. Silos' dimensions: diameter 18m, height 22,7m. Technical assessment was prepared in 2011.

Technical assessment of two RC containers of sewage treatment plant in Jastarnia.

Technical assessment and repair recommendations of the RC tanks for liquid after 20 years of exploitation. Tanks' dimensions: diameter 24m, height 7 m. Technical assessment was prepared in 2010.

Verification of detail design of biological reactor at sewage treatment plant in Witnica.

Technical assessment covered the verification of structural and material solutions together with the verification of static calculations. The tank's main chamber is 22m in diameter and 10m high. Technical assessment was prepared in 2009.